{"product_id":"dual-lite-pld9-2h","title":"Dual Lite PLD9-2H 9W LED Battery Pack, 120 minutes, 120-277V","description":"\u003cb\u003ePRODUCT FAMILY SPECIFICATIONS\u003cbr\u003e\u003c\/b\u003e\u003cspan style=\"background-color: initial;\"\u003e\u003cb\u003eAPPLICATION\u003c\/b\u003e\u003cbr\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cspan style=\"background-color: initial;\"\u003e\u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003eThe Dual-Lite PLD9\/10 is a universal input \u003c\/span\u003e(120-277V) emergency LED battery pack that works with an AC LED driver to allow an LED lighting load to be used in both normal and emergency operation.\u003c\/li\u003e\n\u003cli\u003eWhen normal AC power is lost, the PLD9\/10 operates to provide 9 or 10 watts of constant emergency power at a rated output voltage of 20-56Vdc\u003c\/li\u003e\n\u003cli\u003eThe constant power design provides backup for a minimum of 90 minutes (10 watt output), or 120 minutes (9 watt output) with no loss of emergency lumen output\u003c\/li\u003e\n\u003cli\u003eWhen used with emergency-only LED fixtures, no AC driver is needed\u003c\/li\u003e\n\u003cli\u003eThe UL924 Listing allows for both field and factory installations of suitable LED loads including LED luminaires, DC voltage driven LED replacements for fluorescent lamps and others\u003c\/li\u003e\n\u003c\/ul\u003e\u003c\/span\u003e\u003cb\u003eCONSTRUCTION\u003c\/b\u003e\u003cbr\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cspan style=\"background-color: initial;\"\u003eCompact case constructed of polycarbonate \u003c\/span\u003ethermoplastic.\u003c\/li\u003e\n\u003cli\u003eThe unit contains a solid-state charger with automatic transfer circuit, a 2-wire test switch and LED charging indicator light, and a high-temperature, Nickel-Cadmium battery\u003c\/li\u003e\n\u003c\/ul\u003e\u003cdiv\u003e\n\u003cb\u003e\u003c\/b\u003e\u003cspan style=\"background-color: initial;\"\u003e\u003cb\u003eINSTALLATION\u003cbr\u003e\u003c\/b\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cspan style=\"background-color: initial;\"\u003e\u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003eThe PLD9\/10 emergency battery pack does \u003c\/span\u003enot affect normal LED fixture operation and may be used with either switched or unswitched fixtures\u003c\/li\u003e\n\u003cli\u003eIf a switched fixture is used, an unswitched hot lead must be connected to the emergency ballast\u003c\/li\u003e\n\u003cli\u003eThe emergency battery packs must be fed from the same branch circuit as the AC\u003c\/li\u003e\n\u003c\/ul\u003e\u003c\/span\u003e\n\u003c\/div\u003e\u003cb\u003eLED driver\u003c\/b\u003e\u003cbr\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cspan style=\"background-color: initial;\"\u003eDue to its thermoplastic construction, the \u003c\/span\u003ePLD9\/10 must either be installed inside the fixture, or enclosed if remote mounted outside the fixture\u003c\/li\u003e\n\u003cli\u003eThe PLD emergency battery pack is suitable for use in damp locations where the ambient temperature is between 0°C (32°F) and 55°C (131°F). It is not suitable for installation in heated air outlet fixtures and wet or hazardous location fixtures\u003c\/li\u003e\n\u003c\/ul\u003e\u003cdiv\u003e\n\u003cb\u003eILLUMINATION\u003c\/b\u003e\u003cspan style=\"background-color: initial;\"\u003e\u003cbr\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cspan style=\"background-color: initial;\"\u003e\u003c\/span\u003e\u003cspan style=\"background-color: initial;\"\u003eThe PLD9\/10 will operate an LED load, that \u003c\/span\u003ehas a power rating of 10 watts or greater, for a minimum of 90 minutes , or 9 watts or greater for a minimum of 120 minutes\u003c\/li\u003e\n\u003cli\u003eUsing the LED load’s efficacy in lm\/w, as published by the Design Lights Consortium website (http:\/\/www.designlights.org), Energy Star - Certified Products - product finder website (http:\/\/www.energystar.gov\/productfinder) or given by the luminaire manufacturer on product catalog specification sheets, lumen output can be calculated by multiplying by the PLD9\/10 \u003cspan style=\"background-color: initial;\"\u003eoutput power (10w or 9w).\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\u003c\/span\u003e\n\u003c\/div\u003e\u003cb\u003eCOMPLIANCE\u003c\/b\u003e\u003cbr\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cspan style=\"background-color: initial;\"\u003eUL 924 Recognized and Damp Location \u003c\/span\u003eListed for field installation\u003c\/li\u003e\n\u003cli\u003eUL 1310 Certified (Class 2 output)\u003c\/li\u003e\n\u003cli\u003eCSA C22.2 No. 141 (Canadian Life Safety Standard, PLD10 Only)\u003c\/li\u003e\n\u003cli\u003eNFPA 101 (Life Safety Code)\u003c\/li\u003e\n\u003cli\u003eNFPA 70 ( National Electrical Code)\u003c\/li\u003e\n\u003cli\u003eCEC Title 20 Compliant (CEC Battery Charger Efficiency Standard)\u003c\/li\u003e\n\u003c\/ul\u003e\u003cb\u003eWARRANTY\u003c\/b\u003e\u003cbr\u003e\u003cul\u003e\u003cli\u003e\u003cspan style=\"background-color: initial;\"\u003e5 Year Full Warranty\u003c\/span\u003e\u003c\/li\u003e\u003c\/ul\u003e \u003cbr\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/dual-lite-PLD9-ordering-information.jpg?v=1775811527\"\u003e","brand":"Hubbell Lighting","offers":[{"title":"Default Title","offer_id":53222792692019,"sku":"Dual-Lite-PLD9-2H","price":140.25,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/6625\/4899\/files\/Dual-Lite-PLD9-2H-2.jpg?v=1775811530","url":"https:\/\/proebs.myshopify.com\/products\/dual-lite-pld9-2h","provider":"Electric Bargain Store","version":"1.0","type":"link"}